日本黄色视频在线免费网站|xxxx日本真实自拍一卡|亚州AV无码永久无限精品|琪琪精品视频在线播放免费

EPC
THERMAL INTEGRITY PROFILING – INSTRUMENTATION AND ANALYSIS
Date:2022-10-17 Views:2358 Source:EPC

Thermal Integrity Profiler (TIP) testing was performed by means of Thermal Wire® cables and Thermal Acquisition Ports (TAPs). The TIP system, manufactured by Pile Dynamics, Inc (PDI) in association with FGE, reads concrete temperatures during curing using cables embedded in the concrete.


The Thermal Wire cables consist of temperature sensors spaced every one foot along the length of a wire. For this D-Wall panel, six Thermal Wire Cables were attached along the full length of one of the reinforcement cages prior to placement within panel. Once the cage was installed to agreed depth, a TAP box was attached to each wire, and data acquisition began prior to concrete placement.


During curing of the concrete, the hydrating cement generates heat, increasing the temperature in the shaft. Every 15 minutes, the TAP units automatically record the measured temperature at each sensor location along the length of the wire, generating a profile of temperature versus depth at each increment of time. After the concrete peak temperature has been achieved, each TAP was connected to a TIP processing unit and the data was downloaded for further interpretation in the office.


The TIP results may be evaluated for concrete quality and for location of the reinforcing cages. The overall average temperature for all Thermal Wire readings over the embedded depths can be directly related to the overall volume of concrete installed. Panel integrity may be assessed based on the average temperature measurements from each Thermal Wire at each depth increment. If the measured average temperature versus depth is consistent, the panel is considered to be uniform in shape and quality. Bulges can be identified as localised increases in average temperature, while insufficient concrete quality or section reductions can be identified as localized decreases in average temperature. Anomalies present over more than ten percent of the effective cross-sectional area are normally seen in multiple Thermal Wires at the same depth. Because soil and/or slurry pockets produce no heat, areas of soil intrusion or inclusion are indicated by lower local temperatures.


Reinforcement cage location can be estimated based on the relative temperature difference between an individual Thermal Wire and the average of all wires. Higher individual Thermal Wire temperatures indicate the wire is closer to the center of the shaft, or near a local bulge, while lower individual Thermal Wire temperatures indicate the wire is closer to the soil-pile interface, or a local defect. By viewing diametrically opposite Thermal Wires, instances where a lateral shift of the reinforcing cage has occurred can be determined, if one wire temperature is higher than average and the diametrically opposite wire temperature is lower than average.

主站蜘蛛池模板: 肇庆市| 扬州市| 徐州市| 永顺县| 临沧市| 三门峡市| 苏尼特右旗| 利津县| 土默特右旗| 永修县| 鹤山市| 许昌县| 万盛区| 巩义市| 资源县| 韩城市| 开江县| 浦东新区| 玛纳斯县| 溧阳市| 南昌县| 呼和浩特市| 邮箱| 宁津县| 怀来县| 海南省| 辉南县| 修水县| 江都市| 红原县| 商城县| 荣成市| 临沧市| 滕州市| 潼南县| 黑龙江省| 安多县| 界首市| 灵寿县| 马龙县| 固镇县|