Model:Oxygen Bomb Calorimeter
Use:measuring the heat of combustion or calorific value of a material.
Standard:ISO 1716; ISO1928; ASTM D240; ASTM D4809; ASTM D5468; ASTM D5865; ASTM E711
The bomb calorimeter is the most common device for measuring the heat of combustion or calorific value of a material. With this apparatus a test specimen of specified mass is burned under standardised conditions. The heat of combustion determined under these conditions is calculated on the basis of the observed temperature rise while taking account of heat loss. The combustion process is initiated inside an atmosphere of oxygen in a constant volume container, the bomb, which is a vessel built to withstand high pressures. It is immersed in a stirred water bath, and the whole device is the calorimeter vessel. The calorimeter vessel is also immersed in an outer water bath. The water temperature in the calorimeter vessel and that of the outer bath are both monitored.
The Oxygen Bomb Calorimeter can be used to measure the heat generated from several applications and has been designed to conform to current ASTM, ISO, EN, BS and DIN international standards. The calorific value of the following groups of materials can be measured:
Isoperibolic Operating Mode
An isoperibolic bomb calorimeter is a calorimeter where the jacket temperature is kept at a constant temperature while the calorimeter vessel (bomb and bucket) temperature rises as heat is released by the combustion of a sample. The jacket and bucket temperatures are continuously measured enabling the heat loss to be corrected for after the test.
An embedded control computer, keypad and LCD enables instrument automation, data acquisition and analysis via user friendly menu driven software.
Automatic Temperature Control of Outer Bath
The embedded control computer automatically sets the outer bath temperature. The temperature is measured using two high precision, high resolution platinum resistance thermometers (PRTs). An external thermostatic controller, bath, circulator and cooler is supplied as standard together with a pipette for temperature controlled filling of the calorimeter vessel. This removes human error increasing repeatability and significantly reduces the preparation time between tests.
Oxygen Filling System
To simplify instrument operation the Bomb Calorimeter is fitted with a semi-automatic filling system. The user merely connects the push on coupling and presses the key to fill the bomb with oxygen. The bomb then fills to the desired pressure and automatically switches off. If this pressure is not reached an error message is shown.
Automatic Firing
The embedded computer controls the temperature of the outer bath and shows when the calorimeter vessel temperature has stabilised. At this point the bomb is automatically fired.
Calibration
The Bomb Calorimeter is calibrated by burning certified benzoic acid to determine a constant called the ‘water equivalent’. The instrument can record the water equivalent for several bomb/bucket combinations. For each bomb/bucket combination five calibrations are performed. The software calculates the average of these five calibrations and uses this value as the water equivalent when testing a sample.
Ordering Guide
The Bomb Calorimeter consists of:
Optional accessories: