Model:Flooring Radiant Panel (EN ISO 92391)
Use:Measure the critical radiant flux of horizontally-mounted floor covering systems exposed to a flaming ignition source in a graded radiant heat environment, within a test chamber.
Standard:EN ISO 9239-1, ASTM E648, ASTM E970, NFPA 253, GB/T 11785
Description
This test method is used to measure the critical radiant flux of horizontally-mounted floor covering systems exposed to a flaming ignition source in a graded radiant heat environment, within a test chamber. It can also be used to measure this same critical radiant flux for exposed attic floor cellulose insulation.
The European Union is using this test method for fire classification of flooring products, throughout European Member States.
The radiant heat is applied by means of a gas-fuelled panel, inclined at 30°, and directed at a horizontally mounted floor covering system specimen. The radiant panel generates a radiant energy flux distribution ranging from a nominal maximum of 10.9 kW/m2 to a minimum of 1.1 kW/m2.
A small stainless steel pilot burner assists in specimen ignition.
The distance burned until flame-out is reached and converted, by calibration, into an equivalent critical radiant flux, in kW/m2.
A smoke measuring system, according to DIN 50055, is mounted on a separate frame at the exhaust stack.